The HTI oxygen analysis system has been designed to read oxygen concentrations sequentially at multiple levels in order to disclose and thus prevent oxygen pocketing and to also analyze the BIBS breathing gases while in use. The oxygen analyzer itself is a self-contained until which will measure oxygen concentrations from 0% to 100% with an accuracy of ±0.25%.
The oxygen analyzer will alarm if the oxygen levels exceed the upper or lower limits previously set or at any time the oxygen concentration is below 18%.
The oxygen analyzer should be calibrated on a daily basis prior to use.
Monday, February 7, 2011
Lase pumped
Unlike their lamp pumped counterparts, Diode Pumped Lasers use high efficiency, long life solid state diodes as their pump source. The diodes emit light precisely at the Nd:YAG pump band, unlike flash lamps, which emit light in a broad spectrum. The unused light in a lamp pumped laser generates extra heat in the laser rod which must be dissipated by the cooling system. This heat causes thermal effects in the laser rod, and results in a loss of beam quality.
Because the solid state diodes emit light which closely matches the pump band of the rod, minimal excess heat is generated, resulting in better beam quality. An additional benefit is lower power usage, and a significantly smaller cooler. The U.S. Laser Diode Pumped Laser head features a proprietary design utilizing close coupled side pumping for high efficiency and beam circularity, and requires no routine maintenance. The solid state diodes used are only the highest quality, aluminum-free type, and their life expectation is well in excess of 10,000 hours.
Because of the excellent beam quality, U.S.Laser Diode Pumped Lasers can generally be focused to smaller spot sizes, and are excellent lasers for use in laser marking and micro machining. When used in Q-switched mode, diode lasers generally have shorter pulse duration than their lamp pumped counterparts. In many applications a lower power diode pumped laser will do the same job as a higher powered lamp pumped laser. Earlier U.S. Laser systems with lamp pumped lasers can easily be retrofitted with newer style diode pumped lasers.
Because the solid state diodes emit light which closely matches the pump band of the rod, minimal excess heat is generated, resulting in better beam quality. An additional benefit is lower power usage, and a significantly smaller cooler. The U.S. Laser Diode Pumped Laser head features a proprietary design utilizing close coupled side pumping for high efficiency and beam circularity, and requires no routine maintenance. The solid state diodes used are only the highest quality, aluminum-free type, and their life expectation is well in excess of 10,000 hours.
Because of the excellent beam quality, U.S.Laser Diode Pumped Lasers can generally be focused to smaller spot sizes, and are excellent lasers for use in laser marking and micro machining. When used in Q-switched mode, diode lasers generally have shorter pulse duration than their lamp pumped counterparts. In many applications a lower power diode pumped laser will do the same job as a higher powered lamp pumped laser. Earlier U.S. Laser systems with lamp pumped lasers can easily be retrofitted with newer style diode pumped lasers.
Lazer Analyzer
U.S. Laser Corporation is proud to introduce you to our high quality line of parts and accessories for use with laser systems. This line represents the most popular items we have developed over our > 20 years of service to the laser community. While this catalog demonstrates a cross-section of what we produce, it by no means includes everything we have done or are capable of doing. If after reviewing this catalog, your interest is stimulated in something we produce, or could produce, please call our sales department. Its technically competent staff will be happy to discuss your requirements or ideas. If necessary, our engineering staff will be happy to get involved to assist in providing an economical solution to your needs. Our staff is here to serve you, and I can assure you that we will go the extra mile to earn your business.
In addition to the parts and accessories showcased in this catalog, we also produce a complete line of lasers and laser systems, designed for industrial and OEM use. In fact, all of the accessories in our catalog were designed and produced specifically for use on these systems. If you have a laser system need, browse through the laser systems section of this catalog, then give us a call. Our system's engineers have over 30 years of experience in designing systems for industrial use. Give us a call, put our years of experience to work for you...
In addition to the parts and accessories showcased in this catalog, we also produce a complete line of lasers and laser systems, designed for industrial and OEM use. In fact, all of the accessories in our catalog were designed and produced specifically for use on these systems. If you have a laser system need, browse through the laser systems section of this catalog, then give us a call. Our system's engineers have over 30 years of experience in designing systems for industrial use. Give us a call, put our years of experience to work for you...
Analyzer Value
BMI Fat Analyzer-Functions:
1. Measure the body fat content with the biological resistance of body
2. Can store the parameters of height, weight, age and sex
3. Display basal metabolism value
4. Display in five obesity types: emaciated, standard, hide corpulent, muscle corpulent and corpulent
5. Display the correct result in 6 seconds
6. Can store 9 groups of parameters
7. Potable and easy to store
• Body fat monitor
• BMI value examination
• Heat exhaustion value(basal metabolism)
It is unhealthy to be too fat or too thin
The health problems caused by fat are becoming more and more serious. According to research, many lethal diseases have close relation to fat, like heart disease, II type diabetes, cerebrovascular disease, high blood pressure and cancer. Besides, it can also cause diseases to the respiratory system and the endocrine dyscrasia, etc,.
Being too thin will not only lose the beauty of good figure but also can cause the deficiency of qi and blood, darkish complexion, poor immunity from diseases, the chaos of the immune system and valetudinarianism and you will fall ill if you don’t pay attention to it.
Thus, either being too fat or too thin threatens the health of man. Health Measurer is a kind of instrument which is designed specifically for measuring the content of body fat. It can be used any time to help work out the amount the fat and the value of heat in the body and remind the user to take care of the health.
1. Measure the body fat content with the biological resistance of body
2. Can store the parameters of height, weight, age and sex
3. Display basal metabolism value
4. Display in five obesity types: emaciated, standard, hide corpulent, muscle corpulent and corpulent
5. Display the correct result in 6 seconds
6. Can store 9 groups of parameters
7. Potable and easy to store
• Body fat monitor
• BMI value examination
• Heat exhaustion value(basal metabolism)
It is unhealthy to be too fat or too thin
The health problems caused by fat are becoming more and more serious. According to research, many lethal diseases have close relation to fat, like heart disease, II type diabetes, cerebrovascular disease, high blood pressure and cancer. Besides, it can also cause diseases to the respiratory system and the endocrine dyscrasia, etc,.
Being too thin will not only lose the beauty of good figure but also can cause the deficiency of qi and blood, darkish complexion, poor immunity from diseases, the chaos of the immune system and valetudinarianism and you will fall ill if you don’t pay attention to it.
Thus, either being too fat or too thin threatens the health of man. Health Measurer is a kind of instrument which is designed specifically for measuring the content of body fat. It can be used any time to help work out the amount the fat and the value of heat in the body and remind the user to take care of the health.
Optical clot Detection
Brand Name : SPRING
Model Number : EK-204
Place of Origin : China
Features:
1. 4 positions for reagents.
2. 4-channel analyzer with optical clot detection.
3. Simple operation, holding the manifestation dynamic state curve and the test item and data greatly.
4. Complete report form (time, specific value, INR, density, reference value)
5. 37 heat and 2-8 refrigerate for reagents.
6. Quickly, accurate, the dependable adoption deducts this bottom method, can examine to the fat blood and the jaundice.
7. Can synthesize to print four sets of contrast diagram text data inside placing a printer.
Model Number : EK-204
Place of Origin : China
Features:
1. 4 positions for reagents.
2. 4-channel analyzer with optical clot detection.
3. Simple operation, holding the manifestation dynamic state curve and the test item and data greatly.
4. Complete report form (time, specific value, INR, density, reference value)
5. 37 heat and 2-8 refrigerate for reagents.
6. Quickly, accurate, the dependable adoption deducts this bottom method, can examine to the fat blood and the jaundice.
7. Can synthesize to print four sets of contrast diagram text data inside placing a printer.
Subscribe to:
Posts (Atom)